Numbers you stake
a building on.
Every figure below is sourced from ASTM-accredited third-party test reports available in the spec library.
Installed & Certified
Across hurricane-zone façades, curtain wall systems, and high-performance residential envelopes in 34 states.
Design Pressure Rating
Maximum positive and negative wind load rating. Tested and documented under ASTM E1300 protocols for Category 5 exposure.
Thermal Performance Achieved
Triple-silver Low-E with 90% argon fill. Verified under NFRC 100 simulation — eligible for LEED EA Credit documentation.
First-Article Test Pass Rate
Across 2,400+ first-article qualification tests over 8 years. Mill cert accuracy verified against independent lab results.
Four product lines.
One data standard.
Every SKU ships with a traceable mill cert, first-article test report, and spectral data file. No submittal package left incomplete.
Heat-Strengthened Series
Thermally processed float glass with surface compression of 3,500–7,500 psi. Engineered for curtain wall spandrel panels and overhead glazing where partial temper is specified.
Applications
Test Standards
| Parameter | Value |
|---|---|
| Thickness Range | 4mm – 19mm |
| Surface Compression | 3,500 – 7,500 psi |
| Breakage Pattern | Large fragments (ASTM C1048) |
| Max Sheet Size | 130" × 240" |
| Bow Tolerance | ≤ 0.1% of span |
| SHGC (6mm clear) | 0.87 |
| VLT (6mm clear) | 90% |
| U-Value (IGU) | 0.24 BTU/h·ft²·°F |
Spectral Transmittance Curve (Simulated)
Active curtain wall and hurricane-zone projects
Real projects.
Documented results.
Test report summaries and mill cert packages available for each project upon request. All data sourced from ASTM-accredited lab documentation.
One Brickell Tower
+120 psf
Wind Load
0.24
U-Value
62
Floors
Hurricane-zone certification achieved 11 days ahead of schedule. Zero first-article test failures.
Pacific Commons Phase III
+85 psf
Wind Load
0.18
U-Value
28
Floors
LEED EA Credit documentation submitted with spectral data files. U-value 25% below code minimum.
Meridian Healthcare Campus
+70 psf
Wind Load
0.22
U-Value
6
Floors
Mill certs and test reports delivered 72 hours before glass arrival. Procurement manager confirmed zero RFI delays.
Coastal Residences at Bal Harbour
+140 psf
Wind Load
0.21
U-Value
18
Floors
Highest DP rating in project portfolio. SGP interlayer post-break performance verified by independent lab.
Total Installed
With Full Documentation
Cert Delivery Before Glass
Due to Missing Data
In the spec library — data sheets, test reports, IGCC certs, wind-load templates
The complete submittal
package, gated once.
| Standard | Products | Status |
|---|---|---|
| ASTM E1300 | HS6, LAM, IGU | Current |
| ASTM C1048 | HS6 | Current |
| ASTM E2190 | IGU | Current |
| ASTM E2188 | LAM | Current |
| NFRC 100 | LE3, IGU | Current |
| Miami-Dade NOA | LAM, HS6 | Active |
| IGCC | IGU | Current |
| AAMA 501.1 | All | Current |
Product Data Sheets
Full spec sheets per SKU with all performance parameters
Test Report Summaries
ASTM-accredited lab results for structural and thermal tests
Certification Docs
IGCC certificates, Miami-Dade NOAs, NFRC simulation reports
Wind-Load Templates
Pre-filled ASTM E1300 calculation worksheets by exposure category
Download Full
Spec Library
48 documents — data sheets, test reports, IGCC certs, and wind-load calculation templates. Delivered as a single organized archive.
No marketing emails. Your data is used only to route the correct spec package to your project type.